home
product
about us
 
 
Sternum Fixation
Designed to achieve compression across the median sternotomy after open heart surgery
Natural evolution of the innovative Claw sternal closure implant range. Engineered to maximise the compression across the sternum and make implant selection easier
Manubrium Fixation
Designed to achieve compression across the sternotomy (Manubrium) after open heart surgery
Natural evolution of the innovative Claw-link sternal closure implant range. Engineered to maximise the compression across the manubrium and make implant selection easier
Rib Fixation
Allows for quick, efficient fixation of multi-rib trauma in an extreme low profile implant
Ideal instruments or solutions for cardiac surgeries. Designed by surgeons to meet the clinical requirements.
 
Sternum Fixation
superior ◆ safe ◆ speed ◆ stable
 
 
  • The Claw implant combines contemporary philosophy for bone fixation and absolute simplicity in design to give the patient fast return to daily activities and the surgeon confidence in closing sternotomies.
  • Utilizing the essential principles of bone fixation, the Claw implant system creates compression across the sternotomy to create the ultimate in stability and proximity of the bone interfaces.
  • The instrumentation and implant design allow for efficiency of surgical workflow and fixation within minutes.
 
 
  • superior — Innovative no drilling, no screw design
  • safe — Painless, less bleeding and easily re-open
  • speed — <5 mins FAST closure for 4 plates
  • stable — No coronal plane movement, No sagittal plane movement, No cross section movement
 
 
  • Easy to install
  • The device does not need to be drilled or driven into the bone.
  • Reduces dehiscence risks
  • Pure titanium and titanium alloy with proven bio-compatibility
  • Patent design for easy re-open
  • Ideal for osteoporotic bone or poor bone quality
 
All from clinical datas
< 5 Min.
> 500,000
< 0.0001%
Entire Chest Closure Time
Close Chest Numbers
Complaint / Failure Cases
 
superior ◆ safe ◆ speed ◆ stable
UpgradedSternum Fixation
 
 
  • The Claw-link is the natural evolution of the innovative Claw sternal closure implant range.
  • Engineered to maximise the compression across the bone and make implant selection easier, the Claw-link utilises all of the same principles that make the original Claw implant beneficial to both patient and surgeon.
  • Our desire for continual improvement has led to a design where each implant can act across a wider size range to make closing the sternotomy even easier.
 
 
  • superior — Innovative no drilling, no screw design
  • safe — Painless, less bleeding and easily re-open
  • speed — <5 mins FAST closure for 4 plates
  • stable — No coronal plane movement, No sagittal plane movement, No cross section movement
 
 
  • Easy to install
  • The device does not need to be drilled or driven into the bone.
  • Reduces dehiscence risks
  • Pure titanium and titanium alloy with proven bio-compatibility
  • Patent design for easy re-open
  • Ideal for osteoporotic bone or poor bone quality
 
All from clinical datas
< 5 Min.
> 500,000
< 0.0001%
entire chest closure time
close chest numbers
complaint / failure cases
 
Manubrium Fixation
superior ◆ safe ◆ speed ◆ stable
 
 
  • The Claw M is utilises the underlying philosophy of the Claw range and has been specifically designed for closure of the manubrium.
  • Carefully contoured for maximum patient comfort, the Claw M allows for maximum stability of the manubrium whilst respecting the patient morphology.
  • The instrumentation allows for compression across the sternotomy to optimise healing of the bone and stability of the shoulder girdle for fast patient recovery.
 
 
  • superior — Innovative no drilling, no screw design
  • safe — Painless, less bleeding and easily re-open
  • speed — <1 min FAST closure
  • stable — No coronal plane movement, No sagittal plane movement, No cross section movement
 
 
  • Easy to install
  • The device does not need to be drilled or driven into the bone.
  • Reduces dehiscence risks
  • Pure titanium and titanium alloy with proven bio-compatibility
  • Patent design for easy re-open
  • Ideal for osteoporotic bone or poor bone quality
 
All from clinical datas
< 1 Min.
> 500,000
< 0.0001%
Single Manubrium Closure Time
close chest numbers
complaint / failure cases
 
MIS ◆ MRI Safe ◆ Biocompatible
No Drilling ◆ Plasticity
Rib Fixation
 
 
  • The ‘Embrace’ rib fixation allows for quick, efficient fixation of multi-rib trauma in an extreme low profile implant.
  • With no requirement for drilling, the bone is embraced by the implant using first class instrumentation to create a stable fracture site without creating further trauma to the bone.
  • The Embrace can be easily applied to upper posterior ribs which is not achievable with traditional plate and screw systems.
 
 
  • MIS — <6 cm incison
  • MRI Safe — Pure titanium, no iron ion
  • Biocompatible — 2 grams only ,no compression on intercostal nerve
  • No Drilling — Easy to operate,No drill, No screw designed
  • Plasticity — Easy to shape, fits closely and firmly
 
 
 
 
 
  • Easy to install
  • The device does not need to be drilled or driven into the bone.
  • Reduces dehiscence risks
  • Pure titanium and titanium alloy with proven bio-compatibility
  • Patent design for easy re-open Ideal for osteoporotic bone or poor bone quality
 
All from clinical datas
≤ 2.0 g
> 1,000,000
< 0.0001%
Single Plate Weight
Fix Rib Fractures
Complaint / Failure Cases